Kem cho, Morbi and Rajkot! I am **Dilipbhai**, the proprietor of **Shivam Water Solution** on Vajepar Main Road, Morbi. For over 10 years, my team and I have been installing, repairing, and servicing domestic RO purifiers, commercial RO plants, and industrial water softeners across our ceramic hub of Morbi, as well as neighbouring Rajkot.
One of the most common complaints I hear from homeowners when they visit my shop or call me is: *"Dilipbhai, the water flow from my RO faucet has turned into a painful, slow trickle! It takes 5 minutes just to fill a single bottle. What is wrong?"*
In our region, ground water TDS (Total Dissolved Solids) levels can range anywhere from **800 PPM to over 2500 PPM**, especially around industrial areas like Trajpar, Shaktishan, and the industrial belts of Morbi and Rajkot. High TDS and hard water take a heavy toll on your purifier's components. If your domestic RO purifier is experiencing low water pressure or slow flow rate, here is my expert breakdown of what is happening and how to fix it.
---
## 1. Clogged Sediment and Pre-Carbon Filters
In Morbi, tap water and borewell water carry high amounts of fine silt, rust particles, and suspended solids. The outer pre-filter (spun filter) and internal sediment/carbon filters act as the first line of defense.
* **The Cause:** When these filters trap mud, dirt, and chemical impurities over 3 to 6 months, their tiny pores get completely blocked. As a result, water cannot pass through efficiently to reach the RO membrane.
* **The Fix:** Inspect your pre-filter housing outside the RO machine. If the white spun filter has turned dark brown or black, it needs immediate replacement. I recommend changing the pre-filter cartridge every **3 to 4 months** in high-sediment areas of Morbi and Rajkot.
---
## 2. Scales and Salt Choking the RO Membrane
The RO membrane is the heart of your water purifier. It features ultrafine pores (0.0001 microns) that block dissolved salts, heavy metals, and bacteria.
* **The Cause:** Hard water scaling (calcium and magnesium buildup) gradually chokes these pores. When the membrane gets scaled or fouled, purified water production drops drastically, resulting in a thin drip into your storage tank.
* **The Fix:** If your pre-filters are fresh but flow remains extremely slow, your RO membrane has likely reached the end of its life (usually 12 to 18 months depending on TDS). You will need an expert technician to test the membrane pressure and TDS output, and replace it with a genuine high-rejection membrane suitable for Morbi's water profile.
---
## 3. Loss of Air Pressure in the RO Storage Tank
Most wall-mounted and counter-top RO systems use a pressurized hydro-pneumatic storage tank to push water out of your faucet smoothly.
* **The Cause:** Inside the tank, there is an air bladder that maintains pressure (around 6 to 8 PSI when empty). Over time, this air bladder loses pressure or leaks. Without sufficient air pressure inside the tank, water will flow out at a tiny trickle even if the tank is full!
* **How to Check:** Lift your RO tank. Is it heavy (meaning full of water), but water comes out very slowly from the tap? That indicates low air pressure.
* **The Fix:** Use a bicycle pump or portable air compressor with a pressure gauge to pump air back into the tank valve to around 6-8 PSI. If the internal air bladder is ruptured, the tank will need to be replaced.
---
## 4. Failing Booster Pump or Low Input Tap Water Pressure
Reverse Osmosis requires strong water pressure (at least 60 to 80 PSI) to force water through the semi-permeable membrane.
* **The Cause:** If your home's main overhead tank lacks water level, or if your RO system's 24V/36V booster pump head has worn out, the pump cannot generate enough pressure to force water through the membrane.
* **The Fix:** First, check if your main tap supply has proper pressure. If input pressure is fine but the pump is vibrating loudly or making squeaking sounds without producing water, the pump head or pump adapter (SMPS) needs repair or replacement.
---
## 5. Kinked Food-Grade Tubing or Faulty Auto-Shut-Off (ASO) Valve
Sometimes the fix is much simpler than replacing expensive parts:
* **Kinked Pipes:** Check behind the purifier cabinet. Often during routine kitchen cleaning, the flexible 1/4-inch RO pipe gets bent or pinched against the wall, throttling the water flow.
* **Faulty ASO Valve or Solenoid Valve:** If the Auto-Shut-Off valve or Solenoid Valve gets jammed with mineral scale, it restricts water flow into the membrane housing.
---
## Dilipbhai's Pro Maintenance Tips for Morbi & Rajkot Residents
1. **Never run your RO dry:** Ensure supply water is turned on before powering up your machine to protect the booster pump.
2. **Change Pre-Filters Regularly:** Spending a small amount on pre-filters every few months saves your expensive membrane and booster pump from premature failure.
3. **Use Anti-Scalant Dosing:** For borewell water with TDS over 1500 PPM, adding an anti-scalant cartridge prolongs membrane lifespan substantially.
---
## Need Fast & Reliable RO Repair in Morbi or Rajkot?
If you have tried checking the basic tubing and pre-filter but your RO is still giving slow flow, don't risk damaging your system further. At **Shivam Water Solution**, we stock 100% original spare parts, heavy-duty booster pumps, high-TDS membranes, and offer fast same-day home service across Morbi and surrounding areas.
* **Visit Our Shop:** Shivam Water Solution, Vajepar Main Road, Morbi - 363641, Gujarat
* **Call / WhatsApp Dilipbhai directly:** [+91 91730 96727](tel:+919173096727)
Drop by our store for free water TDS testing or give me a call today to schedule a technician visit. Drink pure, safe, and healthy water every day!